A Study on Cooling and Dehumidification Process of a Heat Pump Drying System at Low Temperature

Authors

  • Santosh Author
  • Rajendra Author
  • Varun Author
  • Sandeep Author

Keywords:

steady-state, dehumidification of damp

Abstract

When compared to the traditional drying process, the low-temperature heat pump drying technology has gained
popularity since it improves product quality in postharvest settings. Moist air passing through evaporator coils is
cooled and dehumidified, which primarily affects the heat pump dryer's efficiency. However, there aren't any
relationships between mass and heat transport to help solve the issues. This work presents initial efforts to bridge
the gaps in the heat and mass transfer problem. Basic equations for mass and energy are used to create a
mathematical model. The Taylor series approach was utilized to solve the model's numerical solutions. The study's
findings include the steady-state dehumidification of damp air using simple tube coils.

Downloads

Published

19-07-2015

How to Cite

A Study on Cooling and Dehumidification Process of a Heat Pump Drying System at Low Temperature. (2015). International Journal of Mechanical Engineering Research and Technology , 7(3), 1-11. https://ijmert.com/index.php/ijmert/article/view/44