Understanding the Distribution of Degradation Factors via Enhanced Diagnostics

Authors

  • D. Ramesh Author
  • M. Suresh Author
  • T. Yeshwanth Author
  • S. Kalyan Author
  • D. Murali krishna Author

Keywords:

deterioration, impedance

Abstract

With the use of resistance, activation, and diffusion polarizations, our diagnostics assesses the
transient reaction of the PEFC and uses this response to produce diagnostics parameters. By using this diagnostics
method on PEFC short stack or PEFC single cell with a quadrisection separator, we have been able to clarify the
distribution and degradation factors (the three polarizations). Ultimately, Tsuruga Electric Corporation has used
this diagnostic technique to sell maintenance equipment under the PEFC Performance Diagnostics System (PPSD)
"356 TD" name. The cost of conventional diagnostic equipment is prohibitive, and the analysis time is excessive.
Nevertheless, our device, the 356TD, is far less expensive than traditional ones and can identify deterioration
factors and do an impedance study by monitoring the transient response for roughly a minute. But given that the
reflection of

Downloads

Published

14-04-2018

How to Cite

Understanding the Distribution of Degradation Factors via Enhanced Diagnostics. (2018). International Journal of Mechanical Engineering Research and Technology , 10(3), 1-11. https://ijmert.com/index.php/ijmert/article/view/60